EZ 2000 Manual - Bridge: Camsight

Bridge - Camsight  

Camsight website: www.camsight.com

To activate the bridge, in the Main Menu, click Setup, Program Links. Double click on Camsight in the list. Check the Enabled box, verify the Path of file to open, and review the Additional Properties.  Click OK. You will now have a button in your Chart module labeled 'Camsight'.

Technical Data
This data is provided for troubleshooting purposes.

EZ 2000 sends commands to Camsight via the command line.  The syntax looks like this:

C:cdmcdmcdmxcdmx.exe ;patID;fname;lname;SSN;birthdate

Example:
;5001;John;Smith;123456789;01012000

All the fields automatically get stripped of semicolons and spaces. 

The patient id numbers in Camsight must match the patient id numbers in EZ for the bridge to work.  If you already have existing patients in Camsight, and the numbers do not match EZ then you must do one of the following:
1. Talk to our conversion team about the possibility of altering the patient id's in Camsight
2. Change all the patient id's in Camsight manually.
3. Manually enter in all the patient id's from Camsight as ChartNumbers in EZ. Then, have the bridge use ChartNumber instead of PatNum.

We are not sure yet whether suggestion 1 or 2 is possible.  Suggestion 3 is a hassle.

Also, in Camsight, under Maintenance, Preferences, try changing it from Chart # to Alternate Chart # as a way of making the id's match up.

 

  EZ2000 Plus Dental Software 800-273-5033